PRODUCTS CENTER
Guinea Aluminum ventilated Shielded Window
Category:
GuineaShielded Window
Product Description
Honeycomb Shielded Ventilation Panel
| Frequency | 14KHZ | 100KHZ | 100MHZ | 450MHZ | 1GHZ | 10GHZ | 18GHZ | 40GHZ |
| Shielding effect | ≥100dB | ≥110dB | ≥120dB | ≥140dB | ≥140dB | ≥130dB | ≥120dB | ≥100dB |
Commonly used product model specifications
| Model | Flange Frames | Orifice plate area | depth of hole(mm) | aperture(mm) | Applicable frequency(HZ) |
| KAT-2000-181 | 370×370 | 300×300 | 47 | 5.2 | 14K-18G |
| KAT-2000-182 | 370×670 | 300×600 | 47 | 5.2 | 14K-18G |
| KAT-2000-183 | 670×670 | 600×600 | 47 | 5.2 | 14K-18G |
| KAT-2000-401 | 370×370 | 300×300 | 40 | 3.2 | 14K-40G |
| KAT-2000-402 | 370×670 | 300×600 | 40 | 3.2 | 14K-40G |
| KAT-2000-403 | 670×670 | 600×600 | 40 | 3.2 | 14K-40G |
Other specifications can be customized according to customer needs
●Wind resistance characteristic
47mm thick 5.2 hole wind resistance test results
| Air volume (m3/h) inspection items | 680 | 1000 | 1250 | 1630 | 2000 | 2330 | 2657 |
| Static pressure loss (Pa) | 8.88 | 16.56 | 23.42 | 35.94 | 51.29 | 69.06 | 85.31 |
| Total pressure loss (Pa) | 11.52 | 22.28 | 32.35 | 51.13 | 74.15 | 100.09 | 125.66 |
| Drag coefficient | 4.35 | 3.89 | 3.62 | 3.37 | 3.25 | 3.22 | 3.11 |
Note: The effective area of the tested part is 300mm*300mm
40mm thick 3.2 hole wind resistance test results
| Air volume (m3/h) inspection items | 680 | 1000 | 1250 | 1630 | 2000 | 2330 | 2657 |
| Static pressure loss (Pa) | 11.97 | 21.3 | 29.88 | 44.32 | 61.37 | 76.73 | 93.79 |
| Total pressure loss (Pa) | 14.55 | 27.02 | 35.81 | 59.51 | 84.24 | 107.76 | 134.14 |
| Drag coefficient | 5.49 | 4.72 | 4.34 | 3.92 | 3.69 | 3.47 | 3.32 |
Note: The effective area of the tested part is 300mm*300mm
Dedicated shielding ventilation panels for chassis and cabinets
● Wind resistance characteristics
12.7mm thick 3.2 hole wind resistance test result
| Air volume (m3/h) inspection items | 200 | 800 | 1250 | 1500 | 1800 |
| Static pressure loss (Pa) | 6.2 | 46.3 | 95.9 | 131.6 | 178.8 |
| Total pressure loss (Pa) | 9.9 | 104.8 | 238.8 | 337.4 | 475.1 |
| Drag coefficient | 2.7 | 1.79 | 1.67 | 1.64 | 1.6 |
Note: The effective area of the tested part is 150mm*150mm
● Performance comparison
Different types of shielding ventilation components, the shielding mechanism, shielding performance and wind resistance characteristics are not the same, the engineering design should focus on the shielding and ventilation requirements, and take into account the volume, weight, cost, dust, corrosion and other comprehensive requirements to select the appropriate shielding ventilation components. The following is a comparison of the comprehensive performance of several shielded ventilation components (materials).
| Shield Ventilation Component Types | Shielding performance | wind resistance | Dust resistance | Electrochemical corrosion resistance | Thickness, weight | |
| Applicable frequency band (Hz) | Shielding effectiveness (dB) | |||||
| Aluminium waveguide vent window | 150K~18G | 60~100 | Small Poor | dust filter required Better | Good | Thick and light |
| Steel waveguide vent window | 14K~40G | 80~120 | Small Poor | dust filter required Fair | Average | Thick and heavy |
| Foamed metal vent window | 10K~18G | 90~120 | Small Good | Small Good, corrosion resistance Good |
Good
|
Thin thickness, light weight |
Note:
● The surface stroke resistance characteristic is the characteristic of no air filter, if the air filter is installed, the wind resistance will be increased to a certain extent;
● Because the foamed metal ventilation window material is made of metal, it can be used to filter high temperature gas or corrosive gas compared with other ordinary dustproof materials.
: next page